We would like to set optional cookies to understand how the site is used. Essential cookies keep forms working. Cookie policy.

Home / Insights / Fire ratings for finishes and furniture: what is changing for interior designers

Insights for interior designers

Fire ratings for finishes and furniture: what is changing for interior designers

The way a wall lining’s fire performance is classified changed in 2025. The tests behind every upholstered sofa are under review now. And since 2023 the duty to get them right sits with whoever does the design work. Each change bears on your PI.

Guidance only. Cover depends on your own policy wording; speak to us about your position.

Why a finishes schedule is a compliance document

The Building Regulations require internal linings to resist the spread of flame over their surfaces adequately and, if ignited, to have a rate of heat release or fire growth that is reasonable in the circumstances. Internal linings are the materials or products used in lining any partition, wall, ceiling or other internal structure (Building Regulations 2010, Schedule 1, requirement B2).

That description covers much of an interiors schedule: wallcoverings, timber panelling, acoustic finishes, feature ceilings. Since 1 October 2023, anyone doing design work in England must take all reasonable steps so that work built to the design would comply (Building Regulations 2010, regulation 11K). A finish chosen for its look is also a compliance decision, and it is yours.

On a home refurbishment with no architect, you may hold the principal designer role as well. Principal designer: when to sign

What class each space is expected to reach

Approved Document B gives the classes the government expects linings to reach. Volume 2 covers buildings other than dwellings, such as hotels, restaurants and offices. Dwellings are dealt with in volume 1.

Wall and ceiling lining classifications in Approved Document B volume 2, table 6.1
LocationClassification expected
Circulation spaces, such as corridors and lobbiesB-s3, d2
Other roomsC-s3, d2
Small rooms: up to 30 square metres in non-residential accommodation, up to 4 square metres in residentialD-s3, d2

Source: GOV.UK, Approved Document B, volume 2, table 6.1. The corridor is where the standard is highest, and it is where a decorative wallcovering is most likely to be chosen for effect.

National classes have left Approved Document B

On 2 March 2025 amendments to Approved Document B took effect that removed the national classification system, BS 476, for reaction to fire and for roofs. The European standard is now the only route in the guidance. The change applies to building work in England, with transitional provisions for projects already under way. The national classes for fire resistance follow on 2 September 2029 (GOV.UK, Approved Document B: new updates).

For a designer the effect is practical. A data sheet that quotes only a BS 476 result no longer speaks the language of the approved document. Ask the supplier for the European classification and the report behind it, and check that it covers the product as you intend to use it. If the supplier cannot provide one, that is a question for the fire engineer or building control before the order, not after the inspection.

Upholstered furniture: the 2025 changes and the 2026 consultation

Upholstered furniture for private use in a dwelling must meet the Furniture and Furnishings (Fire) (Safety) Regulations 1988. Amendments in force from 30 October 2025 removed the display label, took a list of baby and children’s products out of scope, and extended the time enforcers have to start proceedings from 6 months to 12. The permanent label is still required (GOV.UK, 2025 amendment guidance).

A wider reform is pending. Between 31 March and 23 June 2026 the government consulted on replacing the current tests with requirements based on a smoulder test, with the aim of keeping a high level of fire safety while reducing the use of chemical flame retardants. It also proposed taking second hand furniture out of scope and moving re-upholstery to general product safety rules. The proposals may change. As we write in November 2026, responses are being analysed and no outcome has been published (GOV.UK, consultation, consultation paper).

Until new regulations are made, the 1988 rules apply to the bespoke sofa, the re-covered armchair and the vintage piece you source for a client’s home. Hotels, restaurants and offices fall under the Fire Safety Order, where the responsible person’s risk assessment governs (Fire Safety Order 2005, article 9).

What a PI policy may do with a fire claim

  • Restrictions. Some PI policies now restrict or exclude fire safety claims, often by endorsement. Read the schedule for a lower limit, an aggregate limit or costs included within it. Fire safety exclusions explained
  • One claim or many. The same lining in every corridor of a hotel may be treated as one claim, with one limit to cover all of it.
  • Putting it right. Paying quietly to replace a finish before opening can be an admission and an unauthorised cost. Ask first.
  • Early notice. A failed inspection or a query from building control can be a circumstance to notify, before any claim is made.
  • Tall residential buildings. In a building of at least 18 metres or 7 storeys with 2 or more residential units, most building work needs Building Safety Regulator approval before it starts (GOV.UK, higher-risk buildings). Insurers ask whether you work in them.
  • Goods you sold. If you supplied the furniture yourself, the wording’s treatment of the sale or supply of goods applies as well.

What to record on every schedule

  1. Beside each wall and ceiling finish, note the type of space, the class expected there and the product’s classification, with the report reference.
  2. Ask for the European classification. Query any data sheet that gives a BS 476 result alone.
  3. For upholstered furniture, record whether the use is domestic or not, the supplier’s confirmation that it complies, and the permanent label.
  4. Record who approved the fire strategy and whose advice you relied on: the fire engineer, the principal designer or building control.
  5. When a product is substituted on site, record who proposed it and who approved it.
  6. Tell us how you do this. We would set it out for insurers, because a studio that can show its checks is easier to underwrite than one that cannot. Fair presentation explained

Specifying for a hotel, a restaurant or a tall building?

Send us your schedule and endorsements, and we will tell you what your policy says about fire safety before you start.

Speak to a PI specialistPI for interior designers

Related: PI for interior designers · Fire safety exclusions · Principal designer: when to sign